{"id":21274,"date":"2022-07-07T15:55:41","date_gmt":"2022-07-07T20:55:41","guid":{"rendered":"\/?p=21274"},"modified":"2023-02-23T18:28:46","modified_gmt":"2023-02-24T00:28:46","slug":"choosing-the-right-fluid-cooler","status":"publish","type":"post","link":"https:\/\/spxcooling.com\/fr\/news\/choosing-the-right-fluid-cooler\/","title":{"rendered":"Choisir le bon refroidisseur de fluide"},"content":{"rendered":"<p>Si vous avez remarqu\u00e9 une baisse de performance, si vous rencontrez des probl\u00e8mes continus ou si vous effectuez des r\u00e9parations fr\u00e9quentes sur votre refroidisseur de liquide, il est peut-\u00eatre temps de remplacer votre appareil. Mais, avec autant d\u2019options disponibles aujourd\u2019hui, choisir le refroidisseur de fluide adapt\u00e9 \u00e0 vos besoins en mati\u00e8re de rejet de chaleur n\u2019est pas une t\u00e2che facile. Quel que soit ce que vous refroidissez dans votre unit\u00e9 de refroidissement en circuit ferm\u00e9, voici un aper\u00e7u des diff\u00e9rentes options disponibles et de ce que chaque type offre \u00e0 votre syst\u00e8me.<\/p>\r\n\r\n\r\n\r\n<div style=\"width: 100%; height: 22px;\"><\/div>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-thumbnail blogthumb\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"\/wp-content\/uploads\/fclp1-150x150.jpg\" alt=\"\" class=\"wp-image-21322\"><\/figure>\r\n\r\n\r\n\r\n<div class=\"blogcopy\">\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">Refroidisseurs de fluides hybrides \u00e0 remplissage\/serpentin<\/h4>\r\n\r\n\r\n\r\n<p>Comme son nom l&#039;indique, ce type de refroidisseur de fluide utilise un milieu de remplissage de tour de refroidissement ouverte en combinaison avec des serpentins de transfert de chaleur pour un refroidissement en boucle ferm\u00e9e. L&#039;ajout de supports de remplissage augmente l&#039;efficacit\u00e9 du transfert de chaleur par rapport aux refroidisseurs de fluide traditionnels \u00e9quip\u00e9s uniquement de serpentins. Les refroidisseurs de fluides hybrides \u00e0 remplissage\/serpentin offrent plusieurs avantages, notamment\u00a0:<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\"><li>Capacit\u00e9 par empreinte la plus \u00e9lev\u00e9e<\/li><li>Consommation d&#039;\u00e9nergie du ventilateur la plus faible<\/li><li>Premier co\u00fbt le plus bas<\/li><li>Choix de mat\u00e9riaux de bobine : cuivre, acier galvanis\u00e9 ou acier inoxydable<\/li><\/ul>\r\n\r\n\r\n\r\n<\/div><div style=\"clear: both\">\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-thumbnail blogthumb\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"\/wp-content\/uploads\/fclp2-150x150.jpg\" alt=\"\" class=\"wp-image-21326\"><\/figure>\r\n\r\n\r\n\r\n<div class=\"blogcopy\">\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">Refroidisseurs de fluide \u00e0 contre-courant \u00e0 tirage induit<\/h4>\r\n\r\n\r\n\r\n<p>Ce type de refroidisseur de fluide populaire n&#039;a que des serpentins \u00e0 tube nu qui servent de surface d&#039;\u00e9change thermique. En fonction de la charge du processus, du mod\u00e8le de refroidisseur de fluide et du co\u00fbt de l&#039;eau dans la r\u00e9gion, ce type de refroidisseur de fluide peut parfois g\u00e9n\u00e9rer des \u00e9conomies op\u00e9rationnelles annuelles, et son point de commutation \u00e0 sec plus \u00e9lev\u00e9 peut contribuer \u00e0 limiter consid\u00e9rablement la consommation d&#039;eau. Globalement, ses principales caract\u00e9ristiques sont les suivantes\u00a0:<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\"><li>Flexibilit\u00e9 du fonctionnement \u00e0 sec<\/li><li>\u00c9conomies d\u2019exploitation annuelles possibles<\/li><li>Premier co\u00fbt plus \u00e9lev\u00e9<\/li><\/ul>\r\n\r\n\r\n\r\n<\/div><div style=\"clear: both\">\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-thumbnail blogthumb\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"\/wp-content\/uploads\/fclp3-150x150.jpg\" alt=\"\" class=\"wp-image-21329\"><\/figure>\r\n\r\n\r\n\r\n<div class=\"blogcopy\">\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">Refroidisseur de fluide \u00e0 ailettes \u00e0 contre-courant \u00e0 tirage induit<\/h4>\r\n\r\n\r\n\r\n<p>Ce refroidisseur de fluide est \u00e9galement une conception \u00ab \u00e0 serpentin uniquement \u00bb \u00e0 contre-courant induit, mais des ailettes \u00e0 surface \u00e9tendue sont ajout\u00e9es aux serpentins de transfert de chaleur. Ces serpentins \u00e0 ailettes offrent une capacit\u00e9 s\u00e8che plus \u00e9lev\u00e9e et un encombrement inf\u00e9rieur \u00e0 celui de leurs homologues \u00e0 tube nu, mais ont g\u00e9n\u00e9ralement un co\u00fbt initial plus \u00e9lev\u00e9. Si vous envisagez un refroidisseur de fluide \u00e0 ailettes \u00e0 contre-courant \u00e0 tirage induit, n&#039;oubliez pas qu&#039;il est livr\u00e9 avec\u00a0:&nbsp;<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\"><li>Capacit\u00e9 de s\u00e9chage sup\u00e9rieure<\/li><li>Encombrement r\u00e9duit (que le tube nu \u00e0 contre-courant)<\/li><li>Premier co\u00fbt plus \u00e9lev\u00e9<\/li><\/ul>\r\n\r\n\r\n\r\n<\/div><div style=\"clear: both\">\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-thumbnail blogthumb\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"\/wp-content\/uploads\/fclp4-150x150.jpg\" alt=\"\" class=\"wp-image-21336\"><\/figure>\r\n\r\n\r\n\r\n<div class=\"blogcopy\">\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">Refroidisseur de fluide \u00e0 contre-courant \u00e0 tirage forc\u00e9<\/h4>\r\n\r\n\r\n\r\n<p>Cette technologie plus ancienne est de moins en moins populaire en raison de la consommation \u00e9lev\u00e9e d\u2019\u00e9nergie des ventilateurs, mais elle est encore courante dans le domaine \u00e0 l\u2019heure actuelle. Beaucoup de ces refroidisseurs de fluide sont remplac\u00e9s par des produits \u00e0 tirage induit, \u00e0 moins qu&#039;ils ne soient utilis\u00e9s dans un syst\u00e8me de conduits int\u00e9rieur o\u00f9 un tirage forc\u00e9 est n\u00e9cessaire. Les principales consid\u00e9rations pour ces mod\u00e8les sont\u00a0:<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\"><li>Capacit\u00e9 statique externe \u00e9lev\u00e9e (applications int\u00e9rieures\/canalis\u00e9es)<\/li><li>Utilise env. \u00c9nergie du ventilateur 2X par rapport au tirage induit<\/li><li>Installations ext\u00e9rieures g\u00e9n\u00e9ralement remplac\u00e9es par un tirage induit<\/li><\/ul>\r\n\r\n\r\n\r\n<\/div><div style=\"clear: both\">\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-thumbnail blogthumb\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"350\" src=\"\/wp-content\/uploads\/fclp6.jpg\" alt=\"\" class=\"wp-image-21347\" srcset=\"https:\/\/spxcooling.com\/wp-content\/uploads\/fclp6.jpg 300w, https:\/\/spxcooling.com\/wp-content\/uploads\/fclp6-257x300.jpg 257w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/figure>\r\n\r\n\r\n\r\n<div class=\"blogcopy\">\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">Refroidisseur de fluide \u00e0 tirage forc\u00e9 \u00e0 profil bas<\/h4>\r\n\r\n\r\n\r\n<p>Comme les autres refroidisseurs de fluide \u00e0 tirage forc\u00e9, ces unit\u00e9s utilisent un ventilateur centrifuge pour forcer l&#039;air \u00e0 travers le serpentin. Mais ces unit\u00e9s ont g\u00e9n\u00e9ralement un ventilateur sur le c\u00f4t\u00e9 pour r\u00e9duire la hauteur du refroidisseur. Les caract\u00e9ristiques comprennent\u00a0:<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\"><li>Capacit\u00e9 statique externe \u00e9lev\u00e9e (applications int\u00e9rieures\/canalis\u00e9es)<\/li><li>Id\u00e9al pour les installations de faible hauteur<\/li><li>Utilise env. \u00c9nergie du ventilateur 2X par rapport au tirage induit<\/li><\/ul>\r\n\r\n\r\n\r\n<\/div><div style=\"clear: both\"><\/div>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">Faire votre choix<\/h4>\r\n\r\n\r\n\r\n<p>En fin de compte, le bon refroidisseur de fluide d\u00e9pend en grande partie des besoins exacts de votre b\u00e2timent. Si vous vous concentrez sur l&#039;efficacit\u00e9 \u00e9nerg\u00e9tique, un produit hybride remplissage\/serpentin peut \u00eatre votre meilleur choix\u00a0; si vous souhaitez fonctionner \u00e0 sec de fa\u00e7on saisonni\u00e8re et que le co\u00fbt initial plus \u00e9lev\u00e9 ne vous d\u00e9range pas, un contre-courant de tirage induit pourrait \u00eatre votre meilleur choix. Pour vous aider \u00e0 choisir le bon refroidisseur de fluide, vous pouvez saisir les exigences de votre syst\u00e8me dans <a href=\"https:\/\/spxcooling.com\/fr\/coolspec\/\">S\u00e9lecteur de produits CoolSpec\u00ae<\/a>, un outil con\u00e7u pour vous aider \u00e0 tirer le meilleur parti de votre syst\u00e8me de refroidissement par \u00e9vaporation. <\/p>\r\n\r\n\r\n\r\n<p>Pour obtenir l&#039;aide d&#039;un repr\u00e9sentant technique dans votre r\u00e9gion, cliquez ci-dessous et nous vous contacterons pour obtenir des informations plus sp\u00e9cifiques sur vos besoins. <strong><a rel=\"noreferrer noopener\" href=\"\/fr\/fluid-coolers\/\" target=\"_blank\">Obtenez de l&#039;aide pour choisir votre refroidisseur de fluide\u00a0:<\/a><\/strong><\/p>\r\n\r\n\r\n\r\n<div style=\"clear: both; width: 100%; height: 22px;\"><\/div>\r\n\r\n\r\n\r\n<p><\/p>\r\n\r\n\r\n\r\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-16018d1d wp-block-buttons-is-layout-flex\"><\/div>","protected":false},"excerpt":{"rendered":"<p>If you\u2019ve noticed a drop in performance, have been experiencing continuous issues or making frequent repairs to your fluid cooler, it may be time to replace your unit. But, with so many options available now, choosing the right fluid cooler for your heat rejection needs is no easy task. Regardless of what you\u2019re cooling in [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":22663,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_et_pb_use_builder":"off","_et_pb_old_content":"<!-- wp:paragraph -->\r\n<p>If you\u2019ve noticed a drop in performance, have been experiencing continuous issues or making frequent repairs to your fluid cooler, it may be time to replace your unit. But, with so many options available now, choosing the right fluid cooler for your heat rejection needs is no easy task. Regardless of what you\u2019re cooling in your closed-circuit cooling unit, here\u2019s a rundown of the different options available and what each type offers for your system.<\/p>\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n<p><\/p>\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n<p><\/p>\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:image {\"id\":21322,\"width\":149,\"height\":174,\"sizeSlug\":\"full\",\"linkDestination\":\"none\"} -->\r\n<figure class=\"wp-block-image size-full is-resized\"><img src=\"\/wp-content\/uploads\/fclp1.jpg\" alt=\"\" class=\"wp-image-21322\" width=\"149\" height=\"174\"\/><\/figure>\r\n<!-- \/wp:image -->\r\n\r\n<!-- wp:heading {\"level\":4} -->\r\n<h4>Fill \/ Coil Hybrid Fluid Coolers<\/h4>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:html -->\r\n<p>As the name implies, this type of fluid cooler uses open cooling tower fill media in combination with heat transfer coils for closed loop cooling. The addition of fill media boosts the heat transfer efficiency versus traditional fluid coolers with coils only. Fill\/coil hybrid Fluid coolers offer several benefits, including:<\/p>\r\n<!-- \/wp:html -->\r\n\r\n<!-- wp:list -->\r\n<ul><li>Highest capacity per footprint<\/li><li>Lowest fan energy usage<\/li><li>Lowest first cost<\/li><li>Coil material choices of copper, galvanized or stainless steel<\/li><\/ul>\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:image {\"id\":21326,\"width\":187,\"height\":218,\"sizeSlug\":\"full\",\"linkDestination\":\"none\"} -->\r\n<figure class=\"wp-block-image size-full is-resized\"><img src=\"\/wp-content\/uploads\/fclp2.jpg\" alt=\"\" class=\"wp-image-21326\" width=\"150\" height=\"218\"\/><\/figure>\r\n<!-- \/wp:image -->\r\n\r\n<!-- wp:heading {\"level\":4} -->\r\n<h4>Induced Draft Counterflow Fluid Coolers<\/h4>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n<p>This popular fluid cooler type has only bare tube serpentine coils that serve as the heat exchange surface. Depending on the process load, fluid cooler model and water cost in the area, this fluid cooler type can sometimes provide operational savings annually, and its higher dry switch point can help to greatly limit water usage. Overall, its main characteristics include:<\/p>\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:list -->\r\n<ul><li>Dry operation flexibility<\/li><li>Possible annual operating savings<\/li><li>Higher first cost<\/li><\/ul>\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:paragraph -->\r\n<p><\/p>\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:image {\"id\":21329,\"width\":237,\"height\":277,\"sizeSlug\":\"full\",\"linkDestination\":\"none\"} -->\r\n<figure class=\"wp-block-image size-full is-resized\"><img src=\"\/wp-content\/uploads\/fclp3.jpg\" alt=\"\" class=\"wp-image-21329\" width=\"150\" \/><\/figure>\r\n<!-- \/wp:image -->\r\n\r\n<!-- wp:heading {\"level\":4} -->\r\n<h4>Induced Draft Counterflow Finned Fluid Cooler<\/h4>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n<p>This fluid cooler is also an induced draft counterflow \u201ccoil only\u201d design, but extended surface fins are added to the heat transfer coils. These finned coils provide higher dry capacity and a lower footprint than its bare tube counterparts, but usually come with a higher cost upfront. If considering an induced draft counterflow finned fluid cooler, remember they come with:\u00a0<\/p>\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:list -->\r\n<ul><li>Higher dry capacity<\/li><li>Smaller footprint (than counterflow bare tube)<\/li><li>Higher first cost<\/li><\/ul>\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:heading {\"level\":4} -->\r\n<h4>Forced Draft Counterflow Fluid Cooler<\/h4>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n<p>This older technology is becoming less popular because of its high fan energy usage, but is still common in the field right now. Many of these fluid coolers are being replaced with induced draft products, unless it\u2019s being used in an indoor ducted system where a forced draft is necessary. The main considerations for these models are:<\/p>\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:list -->\r\n<ul><li>High external static capability (indoor\/ducted applications)<\/li><li>Uses approx. 2X fan energy of induced draft<\/li><li>Outdoor installations usually replaced with induced draft<\/li><\/ul>\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:heading {\"level\":4} -->\r\n<h4>Low Profile Forced Draft Fluid Cooler<\/h4>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n<p>Like other forced draft fluid coolers, these units use a centrifugal fan to force the air through the coil. But these units typically have the blower on the side to reduce the height of the cooler. Characteristics include:<\/p>\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:list -->\r\n<ul><li>High external static capability (indoor\/ducted applications)<\/li><li>Ideal for low height installations<\/li><li>Uses approx. 2X fan energy of induced draft<\/li><\/ul>\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:heading {\"level\":4} -->\r\n<h4>Making Your Choice<\/h4>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n<p>In the end, the right fluid cooler has a lot to do with exactly what your building needs. If you\u2019re focused on energy efficiency, a fill\/coil hybrid product may be your best choice; if you want to operate dry seasonally and don\u2019t mind the higher initial cost, then an induced draft counterflow might be your best bet. For assistance with choosing the right fluid cooler, you can input your system\u2019s requirements into <a href=\"https:\/\/www.spxcooling.com\/coolspec\/\">CoolSpec\u00ae product selector<\/a>, a tool designed to help you get the most out of your evaporative cooling system. To get help from a technical representative in your area, click below and we\u2019ll reach out for more specific information about your needs.<\/p>\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n<p><\/p>\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:buttons {\"layout\":{\"type\":\"flex\",\"justifyContent\":\"center\"}} -->\r\n<div class=\"wp-block-buttons\"><!-- wp:button {\"width\":50,\"style\":{\"border\":{\"radius\":\"100px\"},\"color\":{\"background\":\"#003c84\"}},\"className\":\"is-style-fill\"} -->\r\n<div class=\"wp-block-button has-custom-width wp-block-button__width-50 is-style-fill\"><a class=\"wp-block-button__link has-background\" href=\"\/fluidcoolers\/\" style=\"border-radius:100px;background-color:#003c84\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Get Help Choosing Your Fluid Cooler: <\/strong><\/a><\/div>\r\n<!-- \/wp:button --><\/div>\r\n<!-- \/wp:buttons -->","_et_gb_content_width":"","content-type":"","_relevanssi_hide_post":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[32,30],"tags":[],"class_list":["post-21274","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news-blog","category-news"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v21.2 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Choosing The Right Fluid Cooler - SPX Cooling Technologies<\/title>\n<meta name=\"description\" content=\"If you\u2019re focused on energy efficiency, a fill\/coil hybrid product may be your best choice; if you want to operate dry seasonally and don\u2019t mind the higher initial cost, then an induced draft counterflow might be your best bet.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/spxcooling.com\/fr\/news\/choosing-the-right-fluid-cooler\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Choosing The Right Fluid Cooler\" \/>\n<meta property=\"og:description\" content=\"If you\u2019re focused on energy efficiency, a fill\/coil hybrid product may be your best choice; if you want to operate dry seasonally and don\u2019t mind the higher initial cost, then an induced draft counterflow might be your best bet.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/spxcooling.com\/fr\/news\/choosing-the-right-fluid-cooler\/\" \/>\n<meta property=\"og:site_name\" content=\"SPX Cooling Technologies\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/SPX-Cooling-Technologies-182738268785153\" \/>\n<meta property=\"article:published_time\" content=\"2022-07-07T20:55:41+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-02-24T00:28:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/spxcooling.com\/wp-content\/uploads\/Cooling-Tower-Cost-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"420\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"SPX Cooling Tech, LLC\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"SPX Cooling Tech, LLC\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/spxcooling.com\\\/fr\\\/news\\\/choosing-the-right-fluid-cooler\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/spxcooling.com\\\/fr\\\/news\\\/choosing-the-right-fluid-cooler\\\/\"},\"author\":{\"name\":\"SPX Cooling Tech, LLC\",\"@id\":\"https:\\\/\\\/spxcooling.com\\\/#\\\/schema\\\/person\\\/8b0c7d4f6e160c7cf2deec0d9f6fcefb\"},\"headline\":\"Choosing The Right Fluid Cooler\",\"datePublished\":\"2022-07-07T20:55:41+00:00\",\"dateModified\":\"2023-02-24T00:28:46+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/spxcooling.com\\\/fr\\\/news\\\/choosing-the-right-fluid-cooler\\\/\"},\"wordCount\":589,\"publisher\":{\"@id\":\"https:\\\/\\\/spxcooling.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/spxcooling.com\\\/fr\\\/news\\\/choosing-the-right-fluid-cooler\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/spxcooling.com\\\/wp-content\\\/uploads\\\/Cooling-Tower-Cost-1.jpg\",\"articleSection\":[\"Blog\",\"News\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/spxcooling.com\\\/fr\\\/news\\\/choosing-the-right-fluid-cooler\\\/\",\"url\":\"https:\\\/\\\/spxcooling.com\\\/fr\\\/news\\\/choosing-the-right-fluid-cooler\\\/\",\"name\":\"Choosing The Right Fluid Cooler - SPX Cooling Technologies\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/spxcooling.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/spxcooling.com\\\/fr\\\/news\\\/choosing-the-right-fluid-cooler\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/spxcooling.com\\\/fr\\\/news\\\/choosing-the-right-fluid-cooler\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/spxcooling.com\\\/wp-content\\\/uploads\\\/Cooling-Tower-Cost-1.jpg\",\"datePublished\":\"2022-07-07T20:55:41+00:00\",\"dateModified\":\"2023-02-24T00:28:46+00:00\",\"description\":\"If you\u2019re focused on energy efficiency, a fill\\\/coil hybrid product may be your best choice; if you want to operate dry seasonally and don\u2019t mind the higher initial cost, then an induced draft counterflow might be your best bet.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/spxcooling.com\\\/fr\\\/news\\\/choosing-the-right-fluid-cooler\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/spxcooling.com\\\/fr\\\/news\\\/choosing-the-right-fluid-cooler\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/spxcooling.com\\\/fr\\\/news\\\/choosing-the-right-fluid-cooler\\\/#primaryimage\",\"url\":\"https:\\\/\\\/spxcooling.com\\\/wp-content\\\/uploads\\\/Cooling-Tower-Cost-1.jpg\",\"contentUrl\":\"https:\\\/\\\/spxcooling.com\\\/wp-content\\\/uploads\\\/Cooling-Tower-Cost-1.jpg\",\"width\":600,\"height\":420,\"caption\":\"Cooling Tower Cost\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/spxcooling.com\\\/fr\\\/news\\\/choosing-the-right-fluid-cooler\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/spxcooling.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Choosing The Right Fluid Cooler\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/spxcooling.com\\\/#website\",\"url\":\"https:\\\/\\\/spxcooling.com\\\/\",\"name\":\"SPX Cooling Technologies\",\"description\":\"COOLING TOWER PERFORMANCE, COOLING TOWER PARTS, AND COOLING TOWER SALES\",\"publisher\":{\"@id\":\"https:\\\/\\\/spxcooling.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/spxcooling.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/spxcooling.com\\\/#organization\",\"name\":\"SPX Cooling Technologies, Inc.\",\"url\":\"https:\\\/\\\/spxcooling.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/spxcooling.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"\\\/wp-content\\\/uploads\\\/spxcoolingtowerslogos2023.png\",\"contentUrl\":\"\\\/wp-content\\\/uploads\\\/spxcoolingtowerslogos2023.png\",\"width\":1477,\"height\":268,\"caption\":\"SPX Cooling Technologies, Inc.\"},\"image\":{\"@id\":\"https:\\\/\\\/spxcooling.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/SPX-Cooling-Technologies-182738268785153\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/spx-cooling-technologies\\\/mycompany\\\/?viewAsMember=true\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/spxcooling.com\\\/#\\\/schema\\\/person\\\/8b0c7d4f6e160c7cf2deec0d9f6fcefb\",\"name\":\"SPX Cooling Tech, LLC\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f4d4ded057d1c02236b0ef04896c21a4fc7e2aafe7f0689ee1e646c0255d898c?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f4d4ded057d1c02236b0ef04896c21a4fc7e2aafe7f0689ee1e646c0255d898c?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f4d4ded057d1c02236b0ef04896c21a4fc7e2aafe7f0689ee1e646c0255d898c?s=96&d=mm&r=g\",\"caption\":\"SPX Cooling Tech, LLC\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Choosing The Right Fluid Cooler - SPX Cooling Technologies","description":"Si vous vous concentrez sur l&#039;efficacit\u00e9 \u00e9nerg\u00e9tique, un produit hybride remplissage\/serpentin peut \u00eatre votre meilleur choix\u00a0; si vous souhaitez fonctionner \u00e0 sec de fa\u00e7on saisonni\u00e8re et que le co\u00fbt initial plus \u00e9lev\u00e9 ne vous d\u00e9range pas, un contre-courant de tirage induit pourrait \u00eatre votre meilleur choix.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/spxcooling.com\/fr\/news\/choosing-the-right-fluid-cooler\/","og_locale":"fr_FR","og_type":"article","og_title":"Choosing The Right Fluid Cooler","og_description":"If you\u2019re focused on energy efficiency, a fill\/coil hybrid product may be your best choice; if you want to operate dry seasonally and don\u2019t mind the higher initial cost, then an induced draft counterflow might be your best bet.","og_url":"https:\/\/spxcooling.com\/fr\/news\/choosing-the-right-fluid-cooler\/","og_site_name":"SPX Cooling Technologies","article_publisher":"https:\/\/www.facebook.com\/SPX-Cooling-Technologies-182738268785153","article_published_time":"2022-07-07T20:55:41+00:00","article_modified_time":"2023-02-24T00:28:46+00:00","og_image":[{"width":600,"height":420,"url":"https:\/\/spxcooling.com\/wp-content\/uploads\/Cooling-Tower-Cost-1.jpg","type":"image\/jpeg"}],"author":"SPX Cooling Tech, LLC","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"SPX Cooling Tech, LLC","Dur\u00e9e de lecture estim\u00e9e":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/spxcooling.com\/fr\/news\/choosing-the-right-fluid-cooler\/#article","isPartOf":{"@id":"https:\/\/spxcooling.com\/fr\/news\/choosing-the-right-fluid-cooler\/"},"author":{"name":"SPX Cooling Tech, LLC","@id":"https:\/\/spxcooling.com\/#\/schema\/person\/8b0c7d4f6e160c7cf2deec0d9f6fcefb"},"headline":"Choosing The Right Fluid Cooler","datePublished":"2022-07-07T20:55:41+00:00","dateModified":"2023-02-24T00:28:46+00:00","mainEntityOfPage":{"@id":"https:\/\/spxcooling.com\/fr\/news\/choosing-the-right-fluid-cooler\/"},"wordCount":589,"publisher":{"@id":"https:\/\/spxcooling.com\/#organization"},"image":{"@id":"https:\/\/spxcooling.com\/fr\/news\/choosing-the-right-fluid-cooler\/#primaryimage"},"thumbnailUrl":"https:\/\/spxcooling.com\/wp-content\/uploads\/Cooling-Tower-Cost-1.jpg","articleSection":["Blog","News"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/spxcooling.com\/fr\/news\/choosing-the-right-fluid-cooler\/","url":"https:\/\/spxcooling.com\/fr\/news\/choosing-the-right-fluid-cooler\/","name":"Choosing The Right Fluid Cooler - SPX Cooling Technologies","isPartOf":{"@id":"https:\/\/spxcooling.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/spxcooling.com\/fr\/news\/choosing-the-right-fluid-cooler\/#primaryimage"},"image":{"@id":"https:\/\/spxcooling.com\/fr\/news\/choosing-the-right-fluid-cooler\/#primaryimage"},"thumbnailUrl":"https:\/\/spxcooling.com\/wp-content\/uploads\/Cooling-Tower-Cost-1.jpg","datePublished":"2022-07-07T20:55:41+00:00","dateModified":"2023-02-24T00:28:46+00:00","description":"Si vous vous concentrez sur l&#039;efficacit\u00e9 \u00e9nerg\u00e9tique, un produit hybride remplissage\/serpentin peut \u00eatre votre meilleur choix\u00a0; si vous souhaitez fonctionner \u00e0 sec de fa\u00e7on saisonni\u00e8re et que le co\u00fbt initial plus \u00e9lev\u00e9 ne vous d\u00e9range pas, un contre-courant de tirage induit pourrait \u00eatre votre meilleur choix.","breadcrumb":{"@id":"https:\/\/spxcooling.com\/fr\/news\/choosing-the-right-fluid-cooler\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/spxcooling.com\/fr\/news\/choosing-the-right-fluid-cooler\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/spxcooling.com\/fr\/news\/choosing-the-right-fluid-cooler\/#primaryimage","url":"https:\/\/spxcooling.com\/wp-content\/uploads\/Cooling-Tower-Cost-1.jpg","contentUrl":"https:\/\/spxcooling.com\/wp-content\/uploads\/Cooling-Tower-Cost-1.jpg","width":600,"height":420,"caption":"Cooling Tower Cost"},{"@type":"BreadcrumbList","@id":"https:\/\/spxcooling.com\/fr\/news\/choosing-the-right-fluid-cooler\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/spxcooling.com\/"},{"@type":"ListItem","position":2,"name":"Choosing The Right Fluid Cooler"}]},{"@type":"WebSite","@id":"https:\/\/spxcooling.com\/#website","url":"https:\/\/spxcooling.com\/","name":"Technologies de refroidissement SPX","description":"PERFORMANCES DE LA TOUR DE REFROIDISSEMENT, PI\u00c8CES DE TOUR DE REFROIDISSEMENT ET VENTES DE TOUR DE REFROIDISSEMENT","publisher":{"@id":"https:\/\/spxcooling.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/spxcooling.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/spxcooling.com\/#organization","name":"SPX Technologies de refroidissement, Inc.","url":"https:\/\/spxcooling.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/spxcooling.com\/#\/schema\/logo\/image\/","url":"\/wp-content\/uploads\/spxcoolingtowerslogos2023.png","contentUrl":"\/wp-content\/uploads\/spxcoolingtowerslogos2023.png","width":1477,"height":268,"caption":"SPX Cooling Technologies, Inc."},"image":{"@id":"https:\/\/spxcooling.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/SPX-Cooling-Technologies-182738268785153","https:\/\/www.linkedin.com\/company\/spx-cooling-technologies\/mycompany\/?viewAsMember=true"]},{"@type":"Person","@id":"https:\/\/spxcooling.com\/#\/schema\/person\/8b0c7d4f6e160c7cf2deec0d9f6fcefb","name":"SPX Refroidissement Tech, LLC","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/f4d4ded057d1c02236b0ef04896c21a4fc7e2aafe7f0689ee1e646c0255d898c?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/f4d4ded057d1c02236b0ef04896c21a4fc7e2aafe7f0689ee1e646c0255d898c?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/f4d4ded057d1c02236b0ef04896c21a4fc7e2aafe7f0689ee1e646c0255d898c?s=96&d=mm&r=g","caption":"SPX Cooling Tech, LLC"}}]}},"_links":{"self":[{"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/posts\/21274","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/comments?post=21274"}],"version-history":[{"count":52,"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/posts\/21274\/revisions"}],"predecessor-version":[{"id":21363,"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/posts\/21274\/revisions\/21363"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/media\/22663"}],"wp:attachment":[{"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/media?parent=21274"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/categories?post=21274"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/tags?post=21274"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}