{"id":9671,"date":"2019-01-03T11:43:28","date_gmt":"2019-01-03T17:43:28","guid":{"rendered":"\/?p=9671"},"modified":"2019-10-25T11:44:47","modified_gmt":"2019-10-25T16:44:47","slug":"a-stainless-steel-selection-guide-for-cooling-towers","status":"publish","type":"post","link":"https:\/\/spxcooling.com\/fr\/news\/a-stainless-steel-selection-guide-for-cooling-towers\/","title":{"rendered":"Un guide de s\u00e9lection de l&#039;acier inoxydable pour les tours de refroidissement"},"content":{"rendered":"<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"970\" height=\"555\" src=\"\/wp-content\/uploads\/steel_blog.jpg\" alt=\"A slight difference in carbon content greatly affects the corrosion resistance between the two materials in the welded regions.\" class=\"wp-image-9673\" srcset=\"\/wp-content\/uploads\/steel_blog.jpg 970w, \/wp-content\/uploads\/steel_blog-480x275.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 970px, 100vw\" \/><figcaption>Une l\u00e9g\u00e8re diff\u00e9rence de teneur en carbone affecte grandement la r\u00e9sistance \u00e0 la corrosion entre les deux mat\u00e9riaux dans les r\u00e9gions soud\u00e9es.<br><\/figcaption><\/figure>\n\n\n\n<p>Les ing\u00e9nieurs doivent choisir parmi une vari\u00e9t\u00e9 de types d\u2019acier inoxydable lors de la configuration d\u2019une tour de refroidissement globale. L&#039;acier inoxydable de type 301L (SS), le type 304 SS, voire le type 316 SS, peuvent \u00eatre des options s\u00e9lectionnables pour la structure et les composants de la tour, y compris les bassins d&#039;eau froide, lorsqu&#039;une protection suppl\u00e9mentaire contre la corrosion au-del\u00e0 de l&#039;acier galvanis\u00e9 est souhait\u00e9e.<\/p>\n\n\n\n<p>Comprendre les diff\u00e9rents attributs des mat\u00e9riaux des types d&#039;acier inoxydable peut conduire \u00e0 des choix plus logiques et plus fiables. Le type 301L (le \u00ab L \u00bb d\u00e9signe la version \u00e0 faible teneur en carbone du 301) a une teneur maximale en carbone de 0,03 %, tandis que le type 304 en contient 0,08 %. Cette l\u00e9g\u00e8re diff\u00e9rence de teneur en carbone affecte grandement la r\u00e9sistance \u00e0 la corrosion entre les deux mat\u00e9riaux&nbsp;<em>dans les r\u00e9gions soud\u00e9es.<\/em><\/p>\n\n\n\n<p>Bien que presque identiques en termes de teneur en chrome et de nickel et de capacit\u00e9 \u00e0 r\u00e9sister aux attaques chimiques et \u00e0 la corrosion dans les environnements typiques des tours de refroidissement, la faible teneur en carbone du type 301L offre une r\u00e9sistance \u00e0 la corrosion sup\u00e9rieure au niveau des soudures par rapport au type 304. En dehors de la soudure, ces deux aciers inoxydables Les types d&#039;acier offrent pratiquement la m\u00eame protection contre la corrosion dans les environnements typiques des tours de refroidissement.<\/p>\n\n\n\n<p>D&#039;autres avantages de certaines nuances de type 301L incluent une limite d&#039;\u00e9lasticit\u00e9 et une r\u00e9sistance \u00e0 la traction plus \u00e9lev\u00e9es, ainsi qu&#039;une meilleure r\u00e9sistance \u00e0 la fatigue. Ils s&#039;\u00e9crouissent \u00e9galement plus rapidement, ce qui r\u00e9duit l&#039;amincissement et offre une plus grande r\u00e9sistance dans les zones form\u00e9es.<\/p>\n\n\n\n<p>Dans des conditions extr\u00eames, telles que des environnements \u00e0 pH faible, \u00e0 haute teneur en chlorure, des environnements oxydants ou r\u00e9ducteurs extr\u00eames, une protection suppl\u00e9mentaire contre la corrosion offerte par des mat\u00e9riaux tels que l&#039;acier inoxydable de type 316 peut \u00eatre justifi\u00e9e. L&#039;acier inoxydable de type 316 contient du molybd\u00e8ne, ce qui conf\u00e8re une r\u00e9sistance encore plus grande \u00e0 la corrosion.<\/p>\n\n\n\n<p>La plupart des tours de refroidissement ne sont jamais confront\u00e9es \u00e0 ces environnements extr\u00eames. Choisissez judicieusement en s\u00e9lectionnant les mat\u00e9riaux les mieux adapt\u00e9s \u00e0 votre application. \u00c9vitez d&#039;investir dans des mat\u00e9riaux co\u00fbteux dont votre tour de refroidissement n&#039;aura jamais besoin.&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Engineers must choose from a variety of stainless steel types when configuring a package cooling tower. Type 301L stainless steel (SS), Type 304 SS, even Type 316 SS may be selectable options for tower structure and components, including cold water basins, when additional corrosion protection beyond galvanized steel is desired. Understanding the different material attributes [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":9673,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_et_pb_use_builder":"off","_et_pb_old_content":"","_et_gb_content_width":"","content-type":"","_relevanssi_hide_post":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[32,30],"tags":[],"class_list":["post-9671","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news-blog","category-news"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v21.2 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>A Stainless Steel Selection Guide For Cooling Towers - SPX Cooling Technologies<\/title>\n<meta name=\"description\" content=\"A Stainless Steel Selection Guide For Cooling Towers\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/spxcooling.com\/fr\/news\/a-stainless-steel-selection-guide-for-cooling-towers\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"A Stainless Steel Selection Guide For Cooling Towers\" \/>\n<meta property=\"og:description\" content=\"A Stainless Steel Selection Guide For Cooling Towers\" \/>\n<meta property=\"og:url\" content=\"https:\/\/spxcooling.com\/fr\/news\/a-stainless-steel-selection-guide-for-cooling-towers\/\" \/>\n<meta property=\"og:site_name\" content=\"SPX Cooling Technologies\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/SPX-Cooling-Technologies-182738268785153\" \/>\n<meta property=\"article:published_time\" content=\"2019-01-03T17:43:28+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-10-25T16:44:47+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/spxcooling.com\/wp-content\/uploads\/steel_blog.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"970\" \/>\n\t<meta property=\"og:image:height\" content=\"555\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"SPX Cooling Tech, LLC\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"SPX Cooling Tech, LLC\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/news\\\/a-stainless-steel-selection-guide-for-cooling-towers\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/news\\\/a-stainless-steel-selection-guide-for-cooling-towers\\\/\"},\"author\":{\"name\":\"SPX Cooling Tech, LLC\",\"@id\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/#\\\/schema\\\/person\\\/8b0c7d4f6e160c7cf2deec0d9f6fcefb\"},\"headline\":\"A Stainless Steel Selection Guide For Cooling Towers\",\"datePublished\":\"2019-01-03T17:43:28+00:00\",\"dateModified\":\"2019-10-25T16:44:47+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/news\\\/a-stainless-steel-selection-guide-for-cooling-towers\\\/\"},\"wordCount\":291,\"publisher\":{\"@id\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/news\\\/a-stainless-steel-selection-guide-for-cooling-towers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/spxcooling.com\\\/wp-content\\\/uploads\\\/steel_blog.jpg\",\"articleSection\":[\"Blog\",\"News\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/news\\\/a-stainless-steel-selection-guide-for-cooling-towers\\\/\",\"url\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/news\\\/a-stainless-steel-selection-guide-for-cooling-towers\\\/\",\"name\":\"A Stainless Steel Selection Guide For Cooling Towers - SPX Cooling Technologies\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/news\\\/a-stainless-steel-selection-guide-for-cooling-towers\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/news\\\/a-stainless-steel-selection-guide-for-cooling-towers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/spxcooling.com\\\/wp-content\\\/uploads\\\/steel_blog.jpg\",\"datePublished\":\"2019-01-03T17:43:28+00:00\",\"dateModified\":\"2019-10-25T16:44:47+00:00\",\"description\":\"A Stainless Steel Selection Guide For Cooling Towers\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/news\\\/a-stainless-steel-selection-guide-for-cooling-towers\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/spxcooling.com\\\/es\\\/news\\\/a-stainless-steel-selection-guide-for-cooling-towers\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/news\\\/a-stainless-steel-selection-guide-for-cooling-towers\\\/#primaryimage\",\"url\":\"https:\\\/\\\/spxcooling.com\\\/wp-content\\\/uploads\\\/steel_blog.jpg\",\"contentUrl\":\"https:\\\/\\\/spxcooling.com\\\/wp-content\\\/uploads\\\/steel_blog.jpg\",\"width\":970,\"height\":555,\"caption\":\"A slight difference in carbon content greatly affects the corrosion resistance between the two materials in the welded regions.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/news\\\/a-stainless-steel-selection-guide-for-cooling-towers\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"A Stainless Steel Selection Guide For Cooling Towers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/\",\"name\":\"SPX Cooling Technologies\",\"description\":\"COOLING TOWER PERFORMANCE, COOLING TOWER PARTS, AND COOLING TOWER SALES\",\"publisher\":{\"@id\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/#organization\",\"name\":\"SPX Cooling Technologies, Inc.\",\"url\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"\\\/wp-content\\\/uploads\\\/spxcoolingtowerslogos2023.png\",\"contentUrl\":\"\\\/wp-content\\\/uploads\\\/spxcoolingtowerslogos2023.png\",\"width\":1477,\"height\":268,\"caption\":\"SPX Cooling Technologies, Inc.\"},\"image\":{\"@id\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/SPX-Cooling-Technologies-182738268785153\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/spx-cooling-technologies\\\/mycompany\\\/?viewAsMember=true\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/spxcooling.com\\\/es\\\/#\\\/schema\\\/person\\\/8b0c7d4f6e160c7cf2deec0d9f6fcefb\",\"name\":\"SPX Cooling Tech, LLC\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f4d4ded057d1c02236b0ef04896c21a4fc7e2aafe7f0689ee1e646c0255d898c?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f4d4ded057d1c02236b0ef04896c21a4fc7e2aafe7f0689ee1e646c0255d898c?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f4d4ded057d1c02236b0ef04896c21a4fc7e2aafe7f0689ee1e646c0255d898c?s=96&d=mm&r=g\",\"caption\":\"SPX Cooling Tech, LLC\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"A Stainless Steel Selection Guide For Cooling Towers - SPX Cooling Technologies","description":"Un guide de s\u00e9lection de l&#039;acier inoxydable pour les tours de refroidissement","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/spxcooling.com\/fr\/news\/a-stainless-steel-selection-guide-for-cooling-towers\/","og_locale":"fr_FR","og_type":"article","og_title":"A Stainless Steel Selection Guide For Cooling Towers","og_description":"A Stainless Steel Selection Guide For Cooling Towers","og_url":"https:\/\/spxcooling.com\/fr\/news\/a-stainless-steel-selection-guide-for-cooling-towers\/","og_site_name":"SPX Cooling Technologies","article_publisher":"https:\/\/www.facebook.com\/SPX-Cooling-Technologies-182738268785153","article_published_time":"2019-01-03T17:43:28+00:00","article_modified_time":"2019-10-25T16:44:47+00:00","og_image":[{"width":970,"height":555,"url":"https:\/\/spxcooling.com\/wp-content\/uploads\/steel_blog.jpg","type":"image\/jpeg"}],"author":"SPX Cooling Tech, LLC","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"SPX Cooling Tech, LLC","Dur\u00e9e de lecture estim\u00e9e":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/spxcooling.com\/es\/news\/a-stainless-steel-selection-guide-for-cooling-towers\/#article","isPartOf":{"@id":"https:\/\/spxcooling.com\/es\/news\/a-stainless-steel-selection-guide-for-cooling-towers\/"},"author":{"name":"SPX Cooling Tech, LLC","@id":"https:\/\/spxcooling.com\/es\/#\/schema\/person\/8b0c7d4f6e160c7cf2deec0d9f6fcefb"},"headline":"A Stainless Steel Selection Guide For Cooling Towers","datePublished":"2019-01-03T17:43:28+00:00","dateModified":"2019-10-25T16:44:47+00:00","mainEntityOfPage":{"@id":"https:\/\/spxcooling.com\/es\/news\/a-stainless-steel-selection-guide-for-cooling-towers\/"},"wordCount":291,"publisher":{"@id":"https:\/\/spxcooling.com\/es\/#organization"},"image":{"@id":"https:\/\/spxcooling.com\/es\/news\/a-stainless-steel-selection-guide-for-cooling-towers\/#primaryimage"},"thumbnailUrl":"https:\/\/spxcooling.com\/wp-content\/uploads\/steel_blog.jpg","articleSection":["Blog","News"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/spxcooling.com\/es\/news\/a-stainless-steel-selection-guide-for-cooling-towers\/","url":"https:\/\/spxcooling.com\/es\/news\/a-stainless-steel-selection-guide-for-cooling-towers\/","name":"A Stainless Steel Selection Guide For Cooling Towers - SPX Cooling Technologies","isPartOf":{"@id":"https:\/\/spxcooling.com\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/spxcooling.com\/es\/news\/a-stainless-steel-selection-guide-for-cooling-towers\/#primaryimage"},"image":{"@id":"https:\/\/spxcooling.com\/es\/news\/a-stainless-steel-selection-guide-for-cooling-towers\/#primaryimage"},"thumbnailUrl":"https:\/\/spxcooling.com\/wp-content\/uploads\/steel_blog.jpg","datePublished":"2019-01-03T17:43:28+00:00","dateModified":"2019-10-25T16:44:47+00:00","description":"Un guide de s\u00e9lection de l&#039;acier inoxydable pour les tours de refroidissement","breadcrumb":{"@id":"https:\/\/spxcooling.com\/es\/news\/a-stainless-steel-selection-guide-for-cooling-towers\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/spxcooling.com\/es\/news\/a-stainless-steel-selection-guide-for-cooling-towers\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/spxcooling.com\/es\/news\/a-stainless-steel-selection-guide-for-cooling-towers\/#primaryimage","url":"https:\/\/spxcooling.com\/wp-content\/uploads\/steel_blog.jpg","contentUrl":"https:\/\/spxcooling.com\/wp-content\/uploads\/steel_blog.jpg","width":970,"height":555,"caption":"A slight difference in carbon content greatly affects the corrosion resistance between the two materials in the welded regions."},{"@type":"BreadcrumbList","@id":"https:\/\/spxcooling.com\/es\/news\/a-stainless-steel-selection-guide-for-cooling-towers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/spxcooling.com\/es\/"},{"@type":"ListItem","position":2,"name":"A Stainless Steel Selection Guide For Cooling Towers"}]},{"@type":"WebSite","@id":"https:\/\/spxcooling.com\/es\/#website","url":"https:\/\/spxcooling.com\/es\/","name":"Technologies de refroidissement SPX","description":"PERFORMANCES DE LA TOUR DE REFROIDISSEMENT, PI\u00c8CES DE TOUR DE REFROIDISSEMENT ET VENTES DE TOUR DE REFROIDISSEMENT","publisher":{"@id":"https:\/\/spxcooling.com\/es\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/spxcooling.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/spxcooling.com\/es\/#organization","name":"SPX Technologies de refroidissement, Inc.","url":"https:\/\/spxcooling.com\/es\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/spxcooling.com\/es\/#\/schema\/logo\/image\/","url":"\/wp-content\/uploads\/spxcoolingtowerslogos2023.png","contentUrl":"\/wp-content\/uploads\/spxcoolingtowerslogos2023.png","width":1477,"height":268,"caption":"SPX Cooling Technologies, Inc."},"image":{"@id":"https:\/\/spxcooling.com\/es\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/SPX-Cooling-Technologies-182738268785153","https:\/\/www.linkedin.com\/company\/spx-cooling-technologies\/mycompany\/?viewAsMember=true"]},{"@type":"Person","@id":"https:\/\/spxcooling.com\/es\/#\/schema\/person\/8b0c7d4f6e160c7cf2deec0d9f6fcefb","name":"SPX Refroidissement Tech, LLC","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/f4d4ded057d1c02236b0ef04896c21a4fc7e2aafe7f0689ee1e646c0255d898c?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/f4d4ded057d1c02236b0ef04896c21a4fc7e2aafe7f0689ee1e646c0255d898c?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/f4d4ded057d1c02236b0ef04896c21a4fc7e2aafe7f0689ee1e646c0255d898c?s=96&d=mm&r=g","caption":"SPX Cooling Tech, LLC"}}]}},"_links":{"self":[{"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/posts\/9671","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/comments?post=9671"}],"version-history":[{"count":1,"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/posts\/9671\/revisions"}],"predecessor-version":[{"id":9674,"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/posts\/9671\/revisions\/9674"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/media\/9673"}],"wp:attachment":[{"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/media?parent=9671"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/categories?post=9671"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/spxcooling.com\/fr\/wp-json\/wp\/v2\/tags?post=9671"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}